Part Number Hot Search : 
ST1002DG TSC311 LC5205S MJW16010 M38021E3 AN1232 00C12 IRF2903
Product Description
Full Text Search
 

To Download 7-0002125-181AP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  series 181 thru 183 90 pin staked flex jumpers note: aries specializes in custom design and production. in addition to the standard products shown on this page, special materials, platings, sizes, and configurations can be furnished, depending on quantities. aries reserves the right to change product specifications without notice. features: ? aries 90 pin staked flex jumpers combine thin, flexible, solid copper conductors embedded between layers of tough, flexible, flame-retardant insulation. ? consult factory for cable lengths under 2.000 [50.80]. ? see data sheet 11005 for flat pin staked flex jumpers ? for rohs applications for lead-free soldering use ht cable general specifications: ? standard cable insulation is white ul vw-1, style 2643 flame retardant polyester (mylar) adhesive. ? high temperature flame retardant cable insulation is polyimide (kapton) insulation with acrylic adhesive. ? cable conductors are solid copper with a cross-sectional area equivalent to that of 26 gauge awg. ? female housing is black ul 94v-0 glass-filled stanyl 4/6 nylon. ? female and male ?crimp-on? pins are spring-tempered copper alloy 510. ? female and male pin plating: t = 100? [2.54 m] min. matte tin per astm-b545-97 over 50? min. nickel per astm-ams-qq-n-290 tl = 100? [2.54 m] min. 93/7 tin/lead per sae-ams-p-81728 over 50 ? [1.27m] min. nickel per sae-ams-qq-n-290. ? cable current rating=3 amps ? cable voltage rating=300 volts ? cable dielectric strength=2500 volts/mil, minimum (standard) =4000 volts/mil, minimum (high temp) ? cable insulation resistance=1000 mohms minimum (standard) =100,000 mohms (high temp) ?conductor/contact resistance (avg.) = 20mohms initial (max. 20mohm increase) based on a 2?cable @20c. ?operating temperature=67 to 257f [-55 to 105c]. ? female housing accepts leads .024-.030 [.61-.76] square, .150 [3.81] long minimum. mounting considerations: ? suggested pcb hole size=.032+ .002 .81 + .05] dia. printouts of this document may be out of date and should be considered uncontrolled a ll dimensions : inches [ millimeters ] **aries reserves the right to ship with or without a polarization stripe unless otherwise specified by customer ?a?=no. of conductors x .100 [2.54] ?b?=(no. of conductors -1) x .100 [2.54] kapton is a registered trademark for dupont 11019 rev. k page 1 of 3 all tolerances + .005 [.13] unless otherwise specified xx -xxxx -18x x x xx xx xx-xxxx-181a xx-xxxx-181c xx-xxxx-182b xx-xxxx -182d xx-xxxx-183c xx-xxxx-181ap xx-xxxx-181cp xx-xxxx-182bp xx-xxxx-182dp xx-xxxx-183cp xx-xxxx-181atl xx-xxxx-181ctl xx-xxxx -182btl xx-xxxx-182dtl xx-xxxx-183ctl xx-xxxx-181aht xx-xxxx-181cht xx-xxxx-182bht xx-xxxx-182dht xx-xxxx-183cht xx-xxxx-181aptl xx-xxxx-181cptl xx-xxxx-182bptl xx-xxxx-182dptl xx-xxxx-183cptl xx-xxxx-181apht xx-xxxx-181cpht xx-xxxx-182bpht xx-xxxx-182dpht xx-xxxx-183cpht xx-xxxx-181aptlht xx-xxxx-181cptlht xx-xxxx-182bptlhy xx-xxxx-182dptlht xx-xxxx-183cptlht xx-xxxx-181b xx-xxxx-182a xx-xxxx-182c xx-xxxx-183a xx-xxxx-183d xx-xxxx-181bp xx-xxxx-182ap xx-xxxx-182cp xx-xxxx-183ap xx-xxxx-183dp xx-xxxx-181btl xx-xxxx-182atl xx-xxxx-182ctl xx-xxxx-183atl xx-xxxx-183dtl xx-xxxx-181bht xx-xxxx-182aht xx-xxxx-182cht xx-xxxx-183aht xx-xxxx-183dht xx-xxxx-181bptl xx-xxxx-182aptl xx-xxxx-182cptl xx-xxxx-183aptl xx-xxxx-183dptl xx-xxxx-181bpht xx-xxxx-182apht xx-xxxx-182cpht xx-xxxx-183apht xx-xxxx-183dpht xx-xxxx-181bptlht xx-xxxx-182aptlht xx-xxxx-182cptlht xx-xxxx-183aptlht xx-xxxx-183dptlht no. of conductors: (4 ? 40) optional suffix: ?ht?=high temperature cable insulation optional suffix: ?p?=polarization stripe included cable length: ?l? in inches min. cable length = 2.00? (-002) 2? = -002- 2.5? = -002.5- 2.25? = -002.25- 2.125? = -002.125- jumper series: 181: male both ends 182: male/female (tin) 183: female (tin) both ends bend options: ?a? = both ends bent 90, same direction ?b? = one male end bent 90 ?c? = both ends bent 90, opposite direction ?d? = one female end bent 90 optional suffix: ?tl? = tin/lead plating ordering informa tion bristol, pa usa tel: (215) 781-9956 fax : (215) 781-9845 http://www.arieselec.com ? info@arieselec.com abc
series 181 thru 183 90 pin staked flex jumpers 181a 181b 181c 182a 182b 11019 rev. k page 2 of 3 printouts of this document may be out of date and should be considered uncontrolled bristol, pa usa tel: (215) 781-9956 fax : (215) 781-9845 http://www.arieselec.com ? info@arieselec.com abc
series 181 thru 183 90 pin staked flex jumpers 11019 rev. k page 3 of 3 182c 182d 183a 183c 183d printouts of this document may be out of date and should be considered uncontrolled bristol, pa usa tel: (215) 781-9956 fax : (215) 781-9845 http://www.arieselec.com ? info@arieselec.com abc


▲Up To Search▲   

 
Price & Availability of 7-0002125-181AP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X